Operation Verification

This section provides a method to verify that the machine is operating correctly and can be returned to service. Do these operation verification tests at the end of a maintenance procedure or whenever it is necessary to ensure that the machine is operating properly.

Operation Verification Tests

Error Code Verification Test

Verify that there are no current active logged error codes:

  1. Access either the Error Log (or CPATouchscreen console Control Processing Assembly. Event Log) and record any current active logged error codes:
    • On P10, P30, P30i and P31 LED consoles, Press & hold down the PAUSE/RESET key for 6 seconds minimum to access the Error Log.
    • On P62, P80, and P82 touchscreen consoles, access Service menu (51765761), select About > CPA Even Log.
  2. Resolve any current active logged error code issues.
  3. Delete resolved error codes:
    • On P10, P30, P30i and P31 LED consoles, clear the Error Log, see Error Log & CPA Event Log.
      Press and hold the PAUSE/RESET key for 6 seconds minimum to access the Error Log. If there are no logged error codes, the "Stuck Key" message will show. To remove an error code, press/hold down the QUICK START key until the "NO ERRORS" message shows.
    • . On P62, P80, and P82 touchscreen consoles, error codes cannot be deleted from the CPA Event Log)

Console Verification Tests

Verify the LED console or touchscreen console operation.

LED consoles (P10, P30, P30i and P31) only

  1. Access the Diagnostic/Test menu (51765761) and run the following tests:
    • KEYPAD TEST: Select KEYPAD TEST and follow prompts to run test.
    • DISPLAY TEST: Select DISPLAY TEST and follow prompts to run test.
  2. Exit the Diagnostic Test menu (press the PAUSE/RESET key).

Touchscreen consoles (P62, P80, and P82) only

  1. Access the Service menu (51765761) and perform the following console System Tests (Settings > System Settings > System Tests):
    • Touchscreen Calibration: Follow screen prompts to complete test. When the test is completed the console will automatically exit and return to the System Tests menu.
    • Touchscreen Test: Verify that there is a trace created that follows your finger movement across the touchscreen surface. Select Finish to exit. move your finger and verify that a trace follows
    • Backlight Test: Tests the display backlight brightness. Follow prompts to complete test.
    • RGB Test: Touch the screen to cycle through the test colors: Red, Green, Blue, White, & Black. Returns to the System Tests menu when completed.
    • Numeric Backlight Test: Tests the controls numeric display brightness. Returns to the System Tests menu when completed.
    • Numeric Display Test: Tests the controls numeric display. Returns to the System Tests menu.
  2. Exit the Diagnostic Test menu. (press Back to exit & return to the banner screen)

Motion Controls Test

Verify the machine operation.

  1. Select QUICKSTART to begin a manual workout and operate the treadmill at least 5 minutes. While walking on the unit perform the following tests:
  2. Operate the RESISTANCE motion control from minimum to maximum range while verifying the machine operation.
    • Make sure that the console RESISTANCE paddle control operation is smooth and working correctly.
    • Vary the RESISTANCE from minimum to maximum and back to minimum while pedaling, verify that the pedal resistance increases and decreases as expected.
    • Verify that there were no unusual noises during this test.
    • Verify that the console RESISTANCE indicators and workout displays are showing correct information.
  3. Operate the INCLINE motion controls from minimum to maximum levels while verifying the machine operation.
    • Make sure that the console INCLINE paddle controls operation is smooth and working correctly.
    • Vary the INCLINE from minimum to maximum and back to minimum, verify that the crossramp raises smoothly to the maximum level and returns smoothly to the minimum level.
    • Verify that there were no unusual noises during this test.
    • Verify that the console INCLINE indicators and workout displays are showing correct information.

Heart Rate Test

Verify the Heart Rate operation.

LED consoles (P10, P30, P30i and P31) only

  1. Access the Diagnostic menu (51765761) and run the following tests:
    • HEART RATE TEST: Select HEART RATE TEST and follow prompts run test.

Touchscreen consoles (P62, P80, and P82) only

  1. Access the Service menu (51765761) and run the following test.:
    • HEART RATE TEST: Select HEART RATE TEST and follow prompts run test (System Tests (select System Settings > System Tests).

Return to service

  1. Make sure that the machine is setting level and stable.
  2. On successful completion of these tests, return to service.

 

 

Contact Precor Customer Support (Ph 800.786.8404) with any questions.

Copyright 2016 Precor Incorporated