Power Cord Replacement

About

This procedure provides instruction to remove and replace the power cord.

CAUTION: Use only Precor OEM power cords. Do not remove or otherwise bypass the 3-prong plug with an adapter to use a non-grounded outlet. Do not plug the unit into a power transformer in an attempt to adjust the voltage requirements. Failure to follow these instructions might damage the unit and void the Precor Limited Warranty.

CAUTION: The treadmill requires a 20-amp individual branch circuit grounded per NEC (National Electric Code) guidelines or local region electric code.

Procedure

Review entire procedure before starting.

  1. Set the treadmill circuit breaker to OFF and unplugDisconnect a device power cord plug or cable connector from the power receptacle or outlet. the treadmill’s power cord from the ACAlternating Current: electric current which periodically reverses direction between positive and negative polarity. outlet.
  2. Remove the treadmill’s hood.
  3. Remove the two screws that fasten the AC input panel to the frame. Keep fasteners for replacement installation.
  4. Lift the AC input panel from the frame and rotate it to expose the AC power cord clamp screws.
  5. Remove the fasteners that retain the AC power cord clamp and remove the clamp. Keep fasteners for replacement installation.
  6. Disconnect the AC power cord from the input module.
  7. Feed the end of the replacement AC power cord that mates with the input module through its hole in the frame and firmly insert it into the input module.
  8. Set the AC power cord clamp in its mounting position and install using the previously removed fasteners.
  9. Set the AC input panel in its mounting position and install using the previously removed fasteners.
  10. PlugDevice power cord connector or electrical cable male connector that is inserted into an electrical receptacle "outlet" (also called the plug-in). in the power cord and Switch the input power ON.
  11. Verify treadmill operation per "" and return to service.

.See Also

Replacement Procedures

 

Contact Precor Customer Support (Ph 800.786.8404) with any questions.